Sunray On-line UPS

Click to enlarge image

 Model Number RS UPS

1. Zero transfer time(online)

2. High frequency and dual conversion online technology

3. Advanced PFC technology

4. True sine wave output with less then 3%THD 5.Self-detection when UPS start-up

5. Advanced battery management 7.Cold start feature(DC power on)

6. Automatically charging batteries in UPS off mode

7. Lighting and surge protections

8. Short circuit and overload protections

9. Fun speed automatically changes as load varies

10. Optional external battery pack

11. EMI/RFI noise filter

12. Shutdown and restart schedule

 

 

 

 

 

PARAMETERS??/span>

 

Product Series

J Series Rack Mount 1~6kVA

Model

J1K/1KS

J2K/2KS

J3K/3KS

J6K/6KS

Rated Power

VA/W

1kVA / 0.7kW

2kVA / 1.4kW

3kVA / 2.1kW

6kVA/4.2kW

Input

Nominal Voltage

220VAC

Voltage Range

100/110/120Vac or 220/230/240Vac(selectable)

Frequency Range

40~60Hz

Power Factor

0.97

0.98

Output

Voltage

220VAC ± 2%

220VAC ± 1%

Frequency

50Hz/60HZ ± 0.2Hz (Line mode)
50Hz /60HZ± 0.2Hz ( Battery mode)

Waveform

Sine Wave

Current Crest Ratio

3:1

Bypass

Automatic Transfer

on overload and UPS failure

Before UPS Power-on

Default “NO”, user adjustable to “YES”

Yes

Voltage Range 

80~264VAC (Default), user adjustable within 80~286VAC

176 ~ 261VAC

Transfer Time

0 ms; less than 4 ms from inverter to bypass and vice versa

Zero

LED/LCD indicators

Status

Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault

Audible Alarm

Bypass, On battery mode, Battery low, Overload, Fault

Communications

RS-232 Serial Interface

Intelligent Slot;
OPTIONS:  WEBPOWER SNMP/WEB card, AS400 card or WinPower CMC)

Environmental

Operating Temperature

0 ~ 40°C

Operating Humidity

20 ~ 90% non-condensing

Battery Pack

Type

Internal Batteries

External Battery Pack

Nominal DC Voltage

36VDC

96VDC

240VDC

Backup Time (Full load)

5 min

9 min

5 min

7 min

 

 

 

 

 

 

 

 

 


Related Keywords: UPS , on-line ups , off-line ups , inverter